本系列型號:WAD5015LG05B、WAD5015LG12B、WAD5015MG05B、WAD5015MG12B、WAD5015MG24B、WAD5015HG05B、WAD5015HG12B、WAD5015HG24B、WAD5015UG12B、WAD5015UG24B、WAD5015VG12B、WAD5015VG24BModels in this series: WAD5015LG05B, WAD5015LG12B, WAD5015MG05B, WAD5015MG12B, WAD5015MG24B, WAD5015HG05B, WAD5015HG12B, WAD5015HG24B, WAD5015UG12B, WAD5015UG24B, WAD5015VG12B, WAD5015VG24B
← 同分類:直流風鼓風扇← Category: DC BLOWER FAN完整規格Full specifications
General Specifications
• Motor:4 Poles brushless DC motor
• Frame & Impller:Plastic(UL 94V-0)
• Storage temperature: -40°to + 75°
• Operating temperature: -10°to + 70°
Major Characteristic Parameters
Specifications
|
Model |
Rated Voltage |
Operating Voltage range |
Rated Current |
Speed |
Air Flow |
Air Pressure |
Noise |
||
|
Part NO. |
V |
V |
A |
R.P.M |
CFM |
M³/min |
mmh2o |
inh2o |
dB.A |
|
WAD5015LG05B |
5 |
4.5~5.5 |
0.09 |
3500 |
2.48 |
0.07 |
7.0 |
0.28 |
27.0 |
|
WAD5015LG12B |
12 |
7.0~13.2 |
0.06 |
3500 |
2.48 |
0.07 |
7.0 |
0.28 |
27.0 |
|
WAD5015MG05B |
5 |
4.5~5.5 |
0.12 |
4500 |
3.18 |
0.09 |
11.2 |
0.44 |
32.5 |
|
WAD5015MG12B |
12 |
7.0~13.2 |
0.07 |
4500 |
3.18 |
0.09 |
11.2 |
0.44 |
32.5 |
|
WAD5015MG24B |
24 |
14.0~26.4 |
0.05 |
4500 |
3.18 |
0.09 |
11.2 |
0.44 |
32.5 |
|
WAD5015HG05B |
5 |
4.5~5.5 |
0.18 |
5500 |
3.56 |
0.10 |
14.1 |
0.56 |
37.2 |
|
WAD5015HG12B |
12 |
7.0~13.2 |
0.09 |
5500 |
3.56 |
0.10 |
14.1 |
0.56 |
37.2 |
|
WAD5015HG24B |
24 |
14.0~26.4 |
0.07 |
5500 |
3.56 |
0.10 |
14.1 |
0.56 |
37.2 |
|
WAD5015UG12B |
12 |
7.0~13.2 |
0.15 |
6500 |
4.60 |
0.13 |
22.0 |
0.86 |
45.3 |
|
WAD5015UG24B |
24 |
14.0~26.4 |
0.12 |
6500 |
4.60 |
0.13 |
22.0 |
0.86 |
45.3 |
|
WAD5015VG12B |
12 |
7.0~13.2 |
0.21 |
7500 |
5.25 |
0.15 |
29.7 |
1.17 |
48.5 |
|
WAD5015VG24B |
24 |
14.0~26.4 |
0.15 |
7500 |
5.25 |
0.15 |
29.7 |
1.17 |
48.5 |
• Bearing system B: Two Ball Bearing F:Fluild Bearing S:Sleeve Bearing
|